Karl Fischer reagents have been used for water determination in analytical laboratories for more than half a century. The original formulation, being based on pyridine became out of favour during the past 30 years due to the accompanying hazard and unpleasant odour. Pyridine-free reagents have therefore increased in popularity and now account for the majority of KF titrations.


Karl Fischer electrolyte A Hi-Dry KF

K303

500ml 1LT :

Use in conjunction with Karl Fischer electrolyte C (ROMIL K3146) for cells with diaphragm.

Dgr H:225-301+311+331-314-360D-370- 373 :

Protect from atmospheric moisture.

P:201-210-280-302+352-309+310-403+235 :

(Application) Pyridine-free reagent for coulometric KF titration without diaphragm and anode reagent for cells with diaphragm

Karl Fischer electrolyte AF Hi-Dry KF

for oils and fats

K3072

100ml 500ml :

Use in conjunction with Karl Fischer electrolyte C (ROMIL K3146).

Dgr H:225-301+311+331-314-351-360D-370-372 :

Protect from atmospheric moisture

P:201-210-260-280-305+351+338-308+313 :

(Application) Pyridine-free anode reagent (chloroform/xylene-based) for coulometric KF titration of refined and crude oils and fats


Karl Fischer electrolyte AH Hi-Dry KF

for long-chain hydrocarbons

K3041

500ml :

Use in conjunction with Karl Fischer electrolyte C (ROMIL K3146) for cells with diaphragm.

Dgr H:225-301+311+331-314-360D-335-370-411 :

Protect from atmospheric moisture.

P:201-210-273-280-302+352-309+310-403+235 :

(Application) Pyridine-free reagent for coulometric KF titration of long-chain hydrocarbons without diaphragm and anode reagent with diaphragm

Karl Fischer electrolyte AK Hi-Dry KF

for aldehydes & ketones

K3068

500ml :

Use in conjunction with Karl Fischer electrolyte CK (ROMIL K3179).

Dgr H:226-302-331-314-351-360FD-372 :

Protect from atmospheric moisture.

P:201-210-280-304+340-305+351+338-308+313-403+233 :

(Application) Pyridine-free anode reagent for coulometric KF titration of aldehydes and ketones


Karl Fischer electrolyte AO Hi-Dry KF

K3054

500ml :

Use in conjunction with Karl Fischer electrolyte C (ROMIL K3146) for cells with diaphragm.

Dgr H:225-301+311+331-314-360D-370-373 :

Protect from atmospheric moisture.

P:201-210-280-302+352-309+310-403+235 :

(Application) Pyridine-free reagent for coulometric KF titration with oven without diaphragm and anode reagent with diaphragm

Karl Fischer electrolyte AP Hi-Dry KF

K3087

500ml :

Use in conjunction with Karl Fischer electrolyte C (ROMIL K3146).

Dgr H:225-301+311+331-314-351-360D-370-372 :

Protect from atmospheric moisture.

P:201-210-280-304+340-305+351+338-308+313-403+235 :

(Application) Pyridine-free anode reagent for coulometric KF titration with diaphragm


Karl Fischer electrolyte AR Hi-Dry KF

K3029

500ml :

Dgr H:225-301+311+331-318-360D-370-373 :

Protect from atmospheric moisture.

P:201-210-260-280-301+310-305+351+338 :

(Application) Pyridine-free reagent for coulometric KF titration without diaphragm

Karl Fischer electrolyte C Hi-Dry KF

K3146

25ml 50ml 10x5ml pack :

Use in conjunction with suitable Karl Fischer electrolyte A* for cells with diaphragm.

Dgr H:225-301+311+331-315-318-370-373 :

Protect from atmospheric moisture.

P:210-280-302+352-305+351+338-309+310-403+235 :

(Application) Pyridine-free cathode reagent for coulometric KF titration with diaphragm


Karl Fischer electrolyte CK Hi-Dry KF

for aldehydes & ketones

K3179

50ml :

Use in conjunction with Karl Fischer electrolyte C (ROMIL K3146).

Dgr H:312-314-360Df :

Protect from atmospheric moisture

P:201-280-302+352-305+351+338-308+313 :

(Application) Pyridine-free anode reagent (chloroform/xylene-based) for coulometric KF titration of refined and crude oils and fats

Karl Fischer reagent VC2 Hi-Dry KF

pyridine-free composite

K5102

1LT 2½LT :

Nominal titre 1.0 ml = 2.0 mg ±5% H2O @ 20°C

Dgr H:314-332-360D-401 :

Calibrate before each use.

P:201-273-280c-304+340-305+351+338-308+310 :

(Application) Pyridine-free ready to use reagent for volumetric KF titration


Karl Fischer reagent VC5 Hi-Dry KF

pyridine-free composite

K5105

500ml 1LT 2½LT :

Nominal titre 1.0 ml = 5.0 mg ±5% H2O @ 20°C

Dgr H:314-332-360D-401 :

Calibrate before each use.

P:201-273-280c-304+340-305+351+338-308+310 :

(Application) Pyridine-free ready to use reagent for volumetric KF titration

Karl Fischer reagent VCK5 Hi-Dry KF

pyridine-free composite for aldehydes & ketones

K5235

1LT :

Nominal titre 1.0 ml = 5.0 mg ±5% H2O @ 20°C

Dgr H:314-332-360D-401 :

Calibrate before each use.

P:201-273-280c-304+340-305+351+338-308+310 :

(Application) Pyridine-free ready to use reagent for volumetric KF titration of aldehydes and ketones


Karl Fischer solvent VK Hi-Dry KF

for aldehydes & ketones

K5246

1LT :

Use in conjunction with Karl Fischer reagent VCK5 (ROMIL K5235).

Dgr H:300+310+330-351-361d-372-315-319 :

Protect from atmospheric moisture.

P:201-260v-280f-302+350-304+340-305+351+338-308+313 :

(Application) Solvent for volumetric KF titration of aldehydes and ketones

Karl Fischer solvent VKM Hi-Dry KF

for aldehydes & ketones

K5257

1LT :

Use in conjunction with Karl Fischer reagent VCK5 (ROMIL K5235).

Dgr H:226-302-331-315-318-336-351-360D-372 :

Protect from atmospheric moisture.

P:201-210-280-304+340-305+351+338-308+313-403+233 :

(Application) Solvent for volumetric KF titration of aldehydes and ketones


Karl Fischer solvent VKS Hi-Dry KF

for aldehydes & ketones

K5268

500ml 1LT :

Use in conjunction with Karl Fischer reagent VCK5 (ROMIL K5235).

Dgr H:226-315-318-360D-336 :

Protect from atmospheric moisture.

P:201-210-280-304+340-305+351+338-308+313 :

(Application) Solvent (halogenated hydrocarbon-free) for volumetric KF titration of aldehydes and ketones

Karl Fischer solvent VOC Hi-Dry KF

for oils and fats

K5373

1LT :

Use in conjunction with Karl Fischer reagent VC? (ROMIL K510?).

Dgr H:226-302+312-331-315-319-351-361d-370-372 :

Protect from atmospheric moisture.

P:201-210-261v-280f-304+340-305+351+338-308+313 :

(Application) Solvent (chloroform-based) for volumetric KF titration of oils and fats


Karl Fischer solvent VOH Hi-Dry KF

for oils and fats

K5352

1LT :

Use in conjunction with Karl Fischer reagent VC? (ROMIL K510?).

Dgr H:225-301+311+331-319-370 :

Protect from atmospheric moisture.

P:210-280f-302+352-309+310-403+235 :

(Application) Solvent (hexan-1-ol-based) for volumetric KF titration of oils and fats

Karl Fischer solvent VOX Hi-Dry KF

for crude oils

K5331

1LT 2½LT :

Use in conjunction with Karl Fischer reagent VC? (ROMIL K510?).

Dgr H:225-302-311+331-314-351-360D-370-372 :

Protect from atmospheric moisture.

P:201-210-280-304+340-305+351+338-308+313 :

(Application) Solvent (xylene-based) for volumetric KF titration of crude oils


Karl Fischer solvent VS Hi-Dry KF

K6200

1LT 2½LT :

Use in conjunction with Karl Fischer titrant VT? (ROMIL K621?).

Dgr H:225-301+311+331-314-360D-370 :

Protect from atmospheric moisture.

Replace cap tightly immediately after use.

P:201-210-280-302+352-309+310-403+235 :

(Application) Solvent component (methanol-based) of pyridine-free 2-part system for volumetric KF titration (general purpose)

Karl Fischer solvent VSA1.67 Hi-Dry KF

acid buffer

K6717

1LT :

d 0.79

Dgr H:225-301+311+331-314-360D-370 :

Buffer capacity 1.67 mmol acid/ml

Protect from atmospheric moisture.

Replace cap tightly immediately after use.

P:201-210-280f-302+352-309+310-403+235 :

(Application) Buffer solvent for volumetric KF titration


Karl Fischer solvent VSA5 Hi-Dry KF

acid buffer

K6735

500ml 1LT :

d 0.79

Dgr H:225-301+311+331-314-360D-370 :

Buffer capacity 5 mmol acid/ml

Protect from atmospheric moisture.

Replace cap tightly immediately after use.

P:201-210-280-302+352-309+310-403+235 :

(Application) Buffer solvent for volumetric KF titration

Karl Fischer solvent VSO Hi-Dry KF

for oils

K6524

1LT :

Use in conjunction with Karl Fischer titrant VT? (ROMIL K621?).

Dgr H:225-301+311+331-314-360D-370 :

Protect from atmospheric moisture.

Replace cap tightly immediately after use.

P:201-210-280-302+352-309+310-403+235 :

(Application) Solvent component of pyridine-free 2-part system for volumetric KF titration of oils


Karl Fischer solvent VSOF Hi-Dry KF

for oils and fats

K6586

1LT 2½LT :

Use in conjunction with Karl Fischer titrant VT? (ROMIL K621?).

Dgr H:226-302+312-331-314-351-360D-370-372 :

Protect from atmospheric moisture.

Replace cap tightly immediately after use.

P:201-210-261v-280f-304+340-305+351+338-308+313 :

(Application) Solvent component (chloroform-based) of pyridine-free 2-part system for volumetric KF titration of oils and fat

Karl Fischer titrant VT2 Hi-Dry KF

K6212

500ml 1LT 2½LT :

Nominal titre 1.00 ml = 2.00 mg ±1% H2O @ 20°C

Dgr H:225-301+311+331-370-401 :

Use in conjunction with Karl Fischer solvent VS (ROMIL K6200).

Protect from atmospheric moisture.

Replace cap tightly immediately after use.

P:210-280f-302+352-309+310-403+235 :

(Application) Titrant component of pyridine-free 2-part system for volumetric KF titration


Karl Fischer titrant VT5 Hi-Dry KF

K6215

500ml 1LT 2½LT :

Nominal titre 1.00 ml = 5.00 mg ±0.5% H2O @ 20°C

Dgr H:225-301+311+331-370-401 :

Use in conjunction with Karl Fischer solvent VS (ROMIL K6200).

Protect from atmospheric moisture.

Replace cap tightly immediately after use.

P:210-280f-302+352-309+310-403+235 :

(Application) Titrant component of pyridine-free 2-part system for volumetric KF titration

Karl Fischer calibrant BX5 Hi-Dry KF

H2O 5 mg/ml (water in m-xylene/butan-1-ol)

K7473

100ml 500ml 1LT :

H2O 5.00 mg/ml (5000 ppm) ±0.02 mg/ml

Dgr H:226-312-332-315-318-335-336 :

Matrix: m-Xylene/Butan-1-ol

Protect from atmospheric moisture.

P:210-280-302+352-304+340-305+351+338 :

(Application) Reference material for KF titration (non-hygroscopic matrix) SI-traceable through NIST certified reference material Supplied with Hi-Dry septum seal cap.


Karl Fischer calibrant M5 Hi-Dry KF

H2O 5 mg/ml (water in methanol)

K7582

100ml 500ml 1LT :

d 0.79

Dgr H:225-301+311+331-370 :

H2O 5 mg/ml (5000 ppm) ± 0.02 mg/ml

Matrix: Methanol

Protect from atmospheric moisture.

P:210-280f-302+352-309+310-403+235 :

(Application) Reference material for KF titration SI-traceable through NIST certified reference material Supplied with Hi-Dry septum seal cap.

Karl Fischer calibrant PC Hi-Dry KF

H2O 5.55% (potassium citrate)

K7755

10g :

K3C6H5O7.H2O MW 324.41 CAS [6100-05-6]

H2O 5.55% ±0.05%

Dry at not greater than 105°C for 1 hour before use.

Cool in desiccator.

Application: Reference material for KF titration with oven


Karl Fischer calibrant ST Hi-Dry KF

H2O 15.66% (sodium tartrate)

K7641

100g :

Na2C4H4O6.2H2O MW 230.08 d 1.82 CAS [6106-24-7]

H2O 15.66% ±0.05%

Dry at not greater than 105°C for 1 hour before use.

Cool in desiccator.

(Application) : Cool in desiccator.

Karl Fischer calibrant WS0.1 Hi-Dry KF

H2O 0.1 mg/g

K7017

100ml :

d 1.00

Wng H:226 :

Nominal concentration H2O 0.100 mg/g ±2% @ 20°C

P:210-262 :

Matrix: Anisole/Propylene Carbonate

Protect from atmospheric moisture.

(Application) Reference material for KF titration SI-traceable through NIST certified reference material Supplied with Hi-Dry septum seal cap.


Karl Fischer calibrant WS0.1 Hi-Dry KF

H2O 0.1 mg/g ampoule pack

K7020

10x5ml pack :

d 1.00

Wng H:226 :

Nominal concentration H2O 0.100 mg/g ±5% @ 20°C

P:210-262 :

Matrix: Anisole/Propylene Carbonate

Protect from atmospheric moisture.

(Application) Reference material for KF titration SI-traceable through NIST certified reference material Supplied in pack containing 10 x 5ml sealed glass ampoules.

Karl Fischer calibrant WS1 Hi-Dry KF

H2O 1 mg/g

K7129

100ml :

d 1.00

Wng H:226 :

Nominal concentration H2O 1.00 mg/g ±1% @ 20°C

P:210-262 :

Matrix: Anisole/Propylene Carbonate

Protect from atmospheric moisture.

(Application) Reference material for KF titration SI-traceable through NIST certified reference material Supplied with Hi-Dry septum seal cap.


Karl Fischer calibrant WS1 Hi-Dry KF

H2O 1 mg/g ampoule pack

K7142

10x5ml pack :

d 1.00

Wng H:226 :

Nominal concentration H2O 1.00 mg/g ±2% @ 20

P:210-262 :

Matrix: Anisole/Propylene Carbonate

(Application) Matrix: Anisole/Propylene Carbonate SI-traceable through NIST certified reference material Supplied in pack containing 10 x 5ml sealed glass ampoules.

Karl Fischer calibrant WS10 Hi-Dry KF

H2O 10 mg/g

K7210

100ml :

d 1.00

Dgr H:226-315-318-335-336 :

Nominal concentration H2O 10.0 mg/g ±1% @ 20°C

P:210-280f-302+352-304+340-305+351+338 :

Matrix: Propylene Carbonate/p-Xylene/Butan-1-ol

Protect from atmospheric moisture.

(Application) Reference material for KF titration SI-traceable through NIST certified reference material Supplied with Hi-Dry septum seal cap.


Karl Fischer calibrant WS10 Hi-Dry KF

H2O 10 mg/g ampoule pack

K7264

10x10ml pack :

d 1.00

Dgr H:226-315-318-335-336 :

Nominal concentration H2O 10.0 mg/g ±1% @ 20°C

P:210-280f-302+352-304+340-305+351+338 :

Matrix: Propylene Carbonate/p-Xylene/Butan-1-ol

(Application) Reference material for KF titration SI-traceable through NIST certified reference material Supplied in pack containing 10 x 10ml sealed glass ampoules.

Karl Fischer calibrant X0.1 Hi-Dry KF

H2O 0.1 mg/g (water in m-xylene)

K7362

100ml :

d 0.86

Wng H:226-312+332-315 :

H2O 0.100 mg/g ±2% @ 20°C

P:210-302+352-304+340 :

Matrix: m-Xylene

Protect from atmospheric moisture.

(Application) Reference material for KF titration SI-traceable through NIST certified reference material Supplied with Hi-Dry septum seal cap.


Karl Fischer calibrant X0.1 Hi-Dry KF

H2O 0.1 mg/g (water in m-xylene) ampoule pack

K7381

10x5ml pack :

d 0.86

Wng H:226-312+332-315 :

H2O 0.100 mg/g ±5% @ 20°C

P:210-302+352-304+340 :

Matrix: m-Xylene

Protect from atmospheric moisture.

(Application) Reference material for KF titration SI-traceable through NIST certified reference material Supplied in pack containing 10 x 5ml sealed glass ampoules.